From: Thomas G. Meighan Sent: Friday, April 01, 2005 2:49 PM To: Michael R. Kalish Subject: Hipot Test of 2nd NCSX TF Specimen Mike, I just completed Hi-pot testing of the 2Nd NCSX TF Specimen. Date 4/1/05 Aluminum foil was wrapped around the 12 bar specimen and stayed 4 inches from the end of the bar which acted as a ground plane. A piece of 1/8" dia. wire was attached to each of the 12 conductors. Ground wall test (All conductors to Foil Ground. @ 15KV DC I leakage = 0 micro amps Turn to Turn Test. (All 12 turns to each other.) @ 5KV DC I leakage = 0 micro amps. Tom