NCSX Web Pages  

Project | Management | Physics | Procurement | Manufacturing

NCSX FTP Sites  

Project FTP Server | Supplier FTP Server

Navigation Trail  

Engineering > Design Review > WBS 31
Review Title Magnetic Diagnostic Preliminary Design Review
Date 15 November 2005
Cognizant Engineer George Labik
Responsible Line Manager Dave Johnson
Review Board Chairperson Larry Dudek
Review Board Members Tom Brown, Eric Fredrickson, Dave Johnson, George Labik, Ed Lazarus, Neil Pomphrey, Wayne Reiersen, Steve Raftopoulos, Brent Stratton, Mike Viola, Mike Zarnstorff, Mike Cole, Paul Goranson, Brad Nelson, Larry Dudek
Invitees Tom Brown, Mike Cole, Larry Dudek, Eric Fredrickson, Paul Goranson, Larry Guttadora, Dave Johnson, Doug Labrie, Hutch Neilson, Brad Nelson, Neil Pomphrey, Steve Raftopoulos, Wayne Reiersen, Brent Stratton, Mike Viola, Mike Zarnstorff, Jerry Levine, Frank Malinowski, Judy Malsbury, Mike Williams, Ed Lazarus, Neil Pomphrey, Wayne Reiersen
Attendees Tom Brown, Mike Cole, Larry Dudek, Eric Fredrickson, Paul Goranson, Dave Johnson, Ed Lazarus, Hutch Neilson, Brad Nelson, Neil Pomphrey, Wayne Reiersen, Brent Stratton, Mike Viola, Mike Zarnstorff, Irving Zatz, Jeff Makiel, Jon Menard
Charge  
Design Review Material

Announcement

Presentation

Chits and Disposition

Review Board Report

Review Board Report
Items Reviewed

Sat Unsat

Comments

Appropriate requirements identified    
Development plans and schedules
Regulatory compliance including USQD and NEPA    
Disposition of CHITS from previous reviews    
Cost objectives    

Other review objectives addressed

(Attachment 4 of ENG-033)

 

Summary of Results

The requirements are well defined. and the design addresses the requirements.  Interface Design has been defined and a plan for installation has been developed.  Potential Interferences have been identified and addressed.  Schedule and budget appear to be adequate.

Disposition

(check  one)

 1  Acceptable
 Acceptable pending resolution of concerns - CHITS identified above must be resolved prior to installation.
 1 Incomplete - Additional design work is required prior to another design review.

Cog Engineer Close-out

(check  when done)

 
 1 Action required by Disposition is complete

Privacy and Security Notice

Please forward comments and questions to the Webmaster