| Review
          Title | Rogowski Coil CDR | 
      
        | Date | 18 April  2007 | 
      
        | Cognizant
          Engineer | George Labik | 
      
        | Responsible Line Manager | Brent Stratton | 
      
        | Review Board Chairperson | Mike Zarnstorff | 
      
        | Review Board Members | George Labik, Robert Kaita, 
		Mike Zarnstorff, Stefan Gerhardt, Jim Chrzanowski,           
		Geoff  Gettelfinger | 
      
        | Invitees | George Labik, Tom Brown, Jim 
		Chrzanowski, Larry Dudek, Stefan Gerhardt, Geoff Gettelfinger, Bob 
		Kaita, Wayne Reiersen, Brent Stratton, Mike Viola, Mike Zarnstorff, Mike 
		Cole, Paul Goranson, Brad Nelson. | 
      
        | Attendees | Jim Chrzanowski, Stefan 
	Gerhardt, Bob Kaita, Geoff Gettelfinger, Hutch Neilson, Mike Zarnstorff,  
	Paul (P.J.) Fogarty, Fred Dahlgren, Larry Guttadora | 
      
        | Charge | 1. Define a suitable and 
	workable design 2. Define a set of requirements 3. Obtain approval to proceed to a PDR | 
      
        | Design Review Material | 
        
        Announcement 
        
		Chits and Disposition 
		 
		 
		
		Presentation 
        
		Review Committee Report | 
      
        | Review Board Report |  | 
      
        | Items Reviewed | 
    
     | Sat | Unsat | Comments | 
      
        | Appropriate requirements identified |  |   |  | 
      
        | Development plans and schedules |   |   |  | 
      
        | Regulatory compliance including USQD and NEPA |  |   |  | 
      
        | Disposition of CHITS from previous reviews |  |   |  | 
      
        | Cost 
          objectives |  |    |  | 
      
        | 
          Other 
          review objectives addressed 
          
          (Attachment 4 of ENG-033) |  |   |  | 
      
        | 
          Summary of Results |  | 
      
        | 
          Disposition 
          (check 
     one) | 1 Acceptable | 
      
        | 1 Acceptable pending resolution of concerns - 
    CHITS identified above must be resolved prior to installation. | 
      
        | 1 Incomplete -
    Additional design 
    work is required prior to another design review. | 
      
        | 
          Cog Engineer Close-out 
          (check 
     when done) |  | 
      
        | 1  
    Action required by Disposition is complete |