NCSX Web Pages  

Project | Management | Physics | Procurement | Manufacturing

NCSX FTP Sites  

Project FTP Server | Supplier FTP Server

Navigation Trail  

Engineering > Design Review > WBS 142
Review Title Welded Inner Leg Interfaces Modular Coils A-A, A-B, B-C
Date 18 October 2007
Cognizant Engineer Mike Cole
Responsible Line Manager Larry Dudek
Review Board Chairperson Erik Perry
Review Board Members Erik Perry, Peter Titus, George Biallas, Larry Dudek, George Labik, Bob Parsells
Invitees Mike Cole, Larry Dudek, Erik Perry, Phil Heitzenroeder, Peter Titus, George Biallas, George Labik, Bob Parsells, Mike Viola, Steve Raftopoulos, Hutch Neilson, Bob Simmons,
Attendees Erik Perry, George Labik, George Biallas, Tom Brown, Peter Titus, Ron Strykowsky, Bill Sands, Judy Malsbury, Bob Simmons, Steve Raftopoulos, Jeff Makiel, Don Rej, Larry Dudek, Mike Viola, Frank Malinowski, Bob Ellis, Jerry Levine, Jim Anderson, Rob Goldston, Kevin Freudenberg, Dave Williamson, Paul Fogarty, Sam Dixon, Mike Cole, P. McGinnis,  Paul Goranson, Greg Pitonak
Charge
  1. Are the requirements defined?  What is the proposed design?
  2. What are the results of access studies to-date?
  3. Is the  analysis consistent with the proposed design?
  4. What is the plan to complete final design?
  5. have prior design review chits been addressed?
  6. Are any coil modifications (extra holes) ready to be approved?
  7. Have all technical, cost/schedule, and safety risks been addressed
Design Review Material

Announcement

Chits and Disposition

Presentation

Weld Development Presentation

Sequence Plan

Review Board Report
Items Reviewed

Sat Unsat

Comments

Appropriate requirements identified    
Development plans and schedules
Regulatory compliance including USQD and NEPA    
Disposition of CHITS from previous reviews    
Cost objectives    

Other review objectives addressed

(Attachment 4 of ENG-033)

   

Summary of Results

Disposition

(check  one)

 1 Acceptable
 1 Acceptable pending resolution of concerns - CHITS identified above must be resolved prior to installation.
  1 Incomplete - Additional design work is required prior to another design review.

Cog Engineer Close-out

(check  when done)

 
 1 Action required by Disposition is complete

Privacy and Security Notice