NCR # Originator RAP # Open Date Status Item Nonconforming Condition PPPL/Supplier
WBS 18 - Field Period Assembly
1144 Vulcan NA 12/13/2007 Closed FPA Assembly Fixture #3 As-Shipped configuration discrepencies Supplier
1145 Vulcan NA 12/13/2007 Closed FPA Assembly Fixture #3 Dimensional Discrepancies Supplier
1146 Vulcan NA 12/13/2007 Closed FPA Assembly Fixture #3 Dimensional Discrepancies Supplier
1147 Vulcan NA 12/31/2007 Closed FPA Assembly Fixture #3 Dimensional Discrepancies - hole drilled too deep Supplier 
1157 Vulcan NA 5/1/2008 Needs Dispositioning  FPA Station #3 20. deg wedge assembly Material substitution Supplier
1159 Vulcan NA 5/9/2008 Closed FPA Station #3 Inadequate Material Certifications Supplier
1160 Vulcan NA 5/9/2008 Closed FPA Station #3 Inadequate Material Certifications Supplier
1161 Vulcan NA 5/9/2008 Closed FPA Station #3 Inadequate Material Certifications Supplier
1163 Vulcan NA 5/15/2008 Closed FPA Station #3 Anti Tip Channel Weldment Supplier
1164 Vulcan NA 5/28/2008 Closed FPA Station #3 Anti Tip Channel Weldment Supplier
1165 Vulcan NA 5/28/2008 Closed FPA Station #3 Anti Tip Channel Weldment Supplier
3751 PPPL 3317 3/12/2008 Closed  FPA Station #2 Field Period Assembly Station two Supplier 
3753 PPPL 3317 3/27/2008 Closed FPA Station #2 Welds for the AB2 shim to the A1 Coil has isolated spots of >1.04 mu <1.05 mu at the toe Supplier
3754 PPPL 3317 3/31/2008 Closed FPA Station #2 Welds for the 1/4" Support rod to A-1 B-1 joint shims listed on attached have magnetic permeability >1.3 <1.4 mu. Supplier
3757 PPPL 3317 4/28/2008 Closed FPA Station #2 Three out of seventy monument measurments were .010", .010" and .012" Supplier 
3759 PPPL 3317 5/5/2008 Closed FPA Station #2 Step 6.4.16 of D-NCSX-FPA-002 requires coil racking alignment measurements with a max. .005" RMS deviation. The atual measurements for A2 is .008" Supplier
NA Vulcan NA 5/15/2008 Closed FPA Station #3 Anti Tip Channel Weldment Supplier
3763 PPPL 3317 6/4/2008 Needs Dispositioning  FPA Station #2 Out of Tolerence  Supplier
3767 PPPL 3317 6/24/2008 Needs Dispositioning  FPA Station #2 Deviation from Doc/Procedure  Supplier
3768 PPPL 3342 7/16/2008 Closed Four-Legged Wire Rope Bridle Four-Legged Wire Rope Bridle Sling Supplier
3775 PPPL 3317 8/27/2008 Closed A1, B1, C1 Coil Assemblies  Procedure requires measuring the position of all monuments within .020" of the desired position Supplier
3778 PPPL 3317 9/25/2008 Closed FPA Station #2 BC1 Shear Plate outboard weld to the C2 Coil has weld metal that bridges over to the B2 Coil flange surface. Supplier
3779 PPPL 3317 9/26/2008 Closed FPA Station #2 A2/B2/C2 Coil Assembly Supplier
               
               
             
               
               
               
               
             
               
               
             
               
               
             
               
             
               
               
               
               
               
               
               
               
               
               
               
               
 
 