Differences Between PowerINSPECT 4.0 and PowerINSPECT 4.0 Service Pack 1
    
    Context
    
    this document applies to :
      
        - 
          PowerINSPECT 4.0
PS-Team task 
            3275
      
      Summary
      
        
          Service Pack 1 for PowerINSPECT 4.0 has been released. Service Pack 1 
          is an upgrade for existing installations of PowerINSPECT 4.0. This document 
          describes the differences between the PowerINSPECT 4.0 release and the 
          PowerINSPECT 4.0 Service Pack 1 release.
       
      Description
    
      Service Pack 1 for PowerINSPECT 4.0 has been released. Service Pack 1 
      is an upgrade for existing installations of PowerINSPECT 4.0.
    The bug fixes and changes introduced with PowerINSPECT 4.0 
      Service Pack 1 are as follows:
    
    
      - 
      Fixed a bug where PowerINSPECT would run very slowly if no document was open 
      and the mouse was over the PowerINSPECT window.
      
- 
      Change so that the solution chosen for a measured cylinder is more consistent 
      when the measured points give multiple valid solutions.
      
- 
      Fixed a bug in PowerINSPECT where it would crash when a curve digitised point 
      cloud that included probe orientation changes was committed.
      
- 
      Fixed a bug where PowerINSPECT could crash when opening a previously saved 
      document containing a probed perpendicular line.
      
- 
      Fixed a bug where PowerINSPECT OMV could crash when simulating a CNC probe path 
      containing intermediate probe path entities.
      
- 
      Fixed a bug where PowerINSPECT could crash when the document was closed if 
      range markers had been used to simulate a CNC sequence.
      
- 
      Fixed a bug where PowerINSPECT could crash when a geometric group was deleted 
      after a CNC simulation of its entities had been performed.
      
- 
      Fixed a bug where the CNC simulation would not always take notice of probe head 
      angle changes.
      
- 
      Fixed a bug where Geometry Explorer would position all spheres at 0,0,0, 
      regardless of their position on the CAD.
      
- 
      Fixed a bug where changing an entity's reference plane through graphical 
      picking could cause PowerINSPECT to crash.
      
- 
      Implemented support for inspection device Virtual Cancel in the geometric 
      multi-measure dialog.
      
- 
      Fixed bugs where the user interface for OMV was displayed incorrectly when 
      the display language is set to Japanese.
      
- 
      Fixed a bug where the user interface for the probe database probe builder 
      was displayed incorrectly when the display language is set to Japanese.
      
- 
      Fixed a bug where creating a concentricity entity in PowerINSPECT when the 
      display language was set to French would cause PowerINSPECT to crash.
      
- 
      Fixed a bug where changing the display language after opening and closing a 
      document would cause PowerINSPECT to crash.
      
- 
        Connection protocol updates:
        
          - 
          ActiCM connection: fixed a bug in the protocol script engine where the probe 
          change notification event was not always fired.
          
- 
          ActiCM connection: updates to the connection to support the latest ActiCM 
          functionality.
          
- 
          COORD3 ARCO connection: addition of new connection for COORD3 CMMs. 
          
- 
          Leica Tracker connection: fixed a bug which prevented the trailing 
          I,J,K vector for continuous scanning from being updated.
          
- 
          Leica Tracker connection: fixed a bug where the continuous scanning time mode 
          interval was not being sent to the device.
          
- 
          Leica Tracker connection: fixed a bug where the configured target stability 
          tolerance was not persisted between instances of PowerINSPECT.
          
- 
          Leica Tracker connection: added an explicit stop scanning command.
          
- 
          Leica Tracker connection: account for device repositioning in CNC moves.
          
- 
            Leica Theodolite connection: fixed a bug where homing or locking the tracker 
            onto a target would sometimes fail.
 
- 
      Display translation updates for all languages.
      
- 
        Added the standard Japanese HTML Report template (not included in service pack 
        patch program).
      
- 
        Documentation updates (not included in service pack patch program):
        
          - 
          Updates to the English PowerINSPECT 4.0 Reference Guide.
          
- 
          Addition of the Japanese translation of the PowerINSPECT 4.0 Reference Guide.
          
- 
          Updates to the English What's New in PowerINSPECT 4.0.
          
- 
          Updates to the French translation of What's New in PowerINSPECT 4.0.
          
- 
          Addition of the German translation of What's New in PowerINSPECT 4.0.
          
- 
            Addition of the Italian translation of What's New in PowerINSPECT 4.0.
 
Problem cause
    See the main description above.
    Solution/Workaround
    Install PowerINSPECT 4.0 Service Pack 1.