Differences Between PowerINSPECT 4.3 and PowerINSPECT 4.3 Service
Pack 1
Context
this document applies to :
-
PowerINSPECT 4.3
PS-Team task
5704
Summary
Service Pack 1 for PowerINSPECT 4.3 has been released. Service
Pack 1 is a recommended update for existing installations of
PowerINSPECT 4.3. This document describes the differences between the
PowerINSPECT 4.3 customer release and the PowerINSPECT 4.3 Service
Pack 1 customer release.
Description
Service Pack 1 PowerINSPECT 4.3 has been released. Service
Pack 1 is a recommended update for existing installations of
PowerINSPECT 4.3.
The bug fixes and changes introduced with
PowerINSPECT 4.3 Service Pack 1 are as follows:
-
Fixed a bug where the presence of an invalid or blank FLEX licensing file would
cause PowerINSPECT to ignore a valid PAF licensing file and report licensing
errors.
-
Fixed a bug where PowerINSPECT would crash if the GD&T Wizard is started
when the sequence tree contains an offset plane entity.
-
Fixed a bug where PowerINSPECT's calculation of an entity's nominal values from
a manually created probe path could give the wrong result.
-
Fixed a bug in PowerINSPECT's multi-axis OMV functionality where datum
entities were treated as orientation points.
-
Fixed a bug in PowerINSPECT's multi-axis OMV functionality where
orientation point entities did not account for rotational elements of the
alignment.
-
Fixed a bug in PowerINSPECT's OMV functionality where the calculation of the
From Point did not take the initial alignment into account.
-
Fixed a bug in PowerINSPECT OMV where the auto-orientation button was not
available on the Features tab for probe path creation.
-
Fixed a bug in PowerINSPECT's manual measurement functionality where Delayed
Measure was turned on automatically.
-
Fixed a bug where PowerINSPECT became unresponsive after importing an alignment
from file in the Supravision file format.
-
Fixed a bug where selecting Launch Excel from PowerINSPECT's File menu started
Excel in the background without showing its user interface.
-
Added an option to automatically name surface inspection points according to
the name of the surface they are projected on to.
-
Added the export of surface inspection points' deviation to the SPC
add-in.
-
Connection protocol updates:
-
Fixed a bug which can cause delays in connection protocols processing data
received asynchronously from inspection devices connected using TCP/IP.
-
Upgraded use of Perceptron's ToolKit to version 3.3 to gain support for the
Perceptron V3 sensor and improvements for the Perceptron V5 sensor on a CimCore
arm.
-
Fixed a bug in the support for the Perceptron V5 sensor on a CimCore arm where
the association of the points with laser lines is lost if the lines contain
more than 1000 points.
-
Added support for dual Y CMMs to the Renishaw UCC connection protocol.
-
Changed connection protocol behaviour to make a beep through the PC for contact
points collected during calibration.
Problem cause
See the main description above.
Solution/Workaround
Install PowerINSPECT 4.3 Service Pack 1.