This is a follow on to information supplied by NDT Specialists. All required information has now been submitted and considered for adding
NDT Specialists as a secondary radiographic source.
Please forward the context and attachment to PPPL for their consideration.
 
Attachment Personnel qualification and training.
Equipment capabilities(see below)
Sincerely,
Peter Djordjevich
 
Peter Djordjevich
djord@earthlink.net
EarthLink Revolves Around You.
 
 
----- Original Message -----
From:
To: djord@earthlink.net
Sent: 11/10/2005 8:59:16 AM
Subject: NDT RT
 
 
Here is the additional information.
Chuck Ruud
Quality Manager
MetalTek International
Carondelet Division
cruud@metaltekint.com
636-475-2199
 
 
 
From: Lawrence J. Schneider Sr. [mailto:Larrys@ndtspecialists.com]
Sent: Tuesday, November 08, 2005 11:43 AM
To: Charles.Ruud@MetalTekInt.Com
Cc: Foster Steege
Subject: RE:
Chuck,
Equipment capabilities:
Iridium 192 130 ci Limitations of 3.5" of steel, focal spots sizes typically of .156"
Cobalt 60 100 ci Limitations of 7.5" of steel, focal spot sizes typically of .173"
Phillips 300 Kv X-ray tube, limitation of 2" steel focal spot size of .222" & .083"
GEIT 420 X-ray tube, Limitation of 3.5" of steel, focal spot size of .216" & .098"
24 Mev Betatron Limitation of 20" of steel, focal spot size of .007"
Handling 15 ton and 60 ton crane
Technique
We do not have a technique for the part because we have not seen the part. If there is an available technique we will use it as a guide to establish a new one with our equipment. With our equipment we may be able to economize on an existing technique.
Personnel certification procedure attached.
Lawrence J. Schneider Sr.
Operations Manager
Voice 414-483-9700
Fax 414-483-1392
Cell 414-719-9700
email larrys@ndtspecialists.com
 
This email message and any attachments are for the sole use of the intended recipients and may contain proprietary and/or confidential information which may be privileged or otherwise protected from disclosure. Any unauthorized review, use, disclosure or distribution is prohibited. If you are not the intended recipient, please contact the sender by reply email and destroy the original message and any copies of the message as well as any attachments to the original message.
-----Original Message-----
From: Charles.Ruud@MetalTekInt.Com [mailto:Charles.Ruud@MetalTekInt.Com]
Sent: Monday, November 07, 2005 5:54 PM
To: larrys@ndtspecialists.com
Subject:
Can you supply the requested information to me listed below as #3?
Chuck Ruud
Quality Manager
MetalTek International
Carondelet Division
cruud@metaltekint.com
636-475-2199
 
 
 
I am going to need the three items below to qualify the new RT source. Could you please forward as soon as possible.
Thanks
Peter Djordjevich
Subject: RE: Qualifications New RT Source
Peter,
Sorry to be so slow getting back to this. I agree with the two items you list
#1 Description and capability of equipment.
#2 Technique (I would assume current would be used)
and would only add:
#3 A copy of their Written Practice (certification practices document)
 
 
--
No virus found in this incoming message.
Checked by AVG Anti-Virus.
Version: 7.1.362 / Virus Database: 267.12.8/162 - Release Date: 11/5/2005
 
 
 
--
No virus found in this outgoing message.
Checked by AVG Anti-Virus.
Version: 7.1.362 / Virus Database: 267.12.8/163 - Release Date: 11/8/2005