From: Arthur W. Brooks Sent: Wednesday, May 07, 2008 8:54 AM To: Michael R. Kalish Cc: Horng-Ming Fan Subject: Trim Coils Reaction Loads Attachments: reactions_r0.xls Mike, The attached spreadsheet tabulates the reaction loads for all the trim coils at the support brackets for the iota=0.19 scenario which had a max 80 lb/in running load. The EM loads only are less than what would be calculated using the 80 lb/in x ~ 28in length = 2240 lb as I had suggested. Cool down does have a significant impact on the reactions (~1000 lb by itself) but when added to the EM the net is only slightly higher (2305 lb vs 2240 lb) than what you have been assuming. There is picture included in the spreadsheet (off screen to the right) which identifies the support locations tabulated. Art