From: manuel-majortool-com-offsite Sent: Wednesday, August 10, 2005 10:42 AM To: Thomas G. Brown Cc: Michael E. Viola; mcole@ornl.gov; pgoranson@ornl.gov; bnelson@ornl.gov; Wayne T. Reiersen; Frank A. Malinowski Subject: First 60 degree period metrology inspection Attachments: FULL VESSEL NO PLUG FOR MIKE V.IGS; FULL VESSEL BEST FIT NO PLUG.XLS From Mike Viola, This is an IN process measurement BUT is the condition that will be used to weld into the 120 degree VVSA. However, I wanted to look at this intermediate condition in case there is an area that must be corrected and to allow Major tool the ability to choose whether to make any corrections now or later after the 120 is welded and/or also after the port holes are cut. 90% of the area is OK but there are some points that are quite a bit out. Please look at this IGES file and examine any out of tolerance areas for potential to accept as is. Also included is the verisurf output which provides a picture of the vessel and lists the points with their deviation. Thanks, Mike Viola