From: Arthur W. Brooks Sent: Wednesday, March 28, 2007 2:59 PM To: Michael J. Duco Cc: Thomas G. Brown; Robert A. Ellis; Michael E. Viola; Steve Raftopoulos Subject: RE: A1 and A2 Fiducial Nominals Attachments: A1-2 Tooling Ball Coord After Realignment.xls Mike, Attached are the New Coordinates for the A1 and A2 fiducials following Coil Realignment. The transformation has changed the coordinates by no more than .008" The original numbers were based on a best fit of the data you collected with the coils in the horizontal position on the wedge. You may want to hold onto these in case our coil realignment strategy changes. If you need data in a different format than a spreadsheet let me know and I will convert it in the future. Art -----Original Message----- From: Michael J. Duco Sent: Wednesday, March 28, 2007 7:33 AM To: Arthur W. Brooks Cc: Thomas G. Brown; Robert A. Ellis Subject: RE: A1 and A2 Fiducial Nominals Art, I attempted to select a random set of points while going from horizontal to vertical on the A1 coil effort. Because of the deflections we experienced, I was unable to determine if the points I chose were accurate enough to consider acceptable. In the files I supplied to you, the points that have an arc and a line associated with them are points which were taken during an alignment and are to be considered most accurate (one less level of error). Any points that do not have an arc and a line are subject to add alignment error. If you can filter the points based on this criteria, and compare them to MTM's originals you can compile an accurate set. Mike Michael J. Duco Neutral Beam Cryogenics Princeton University, Plasma Physics Lab Forrestal Campus,Route 1 North at Sayre Dr. P. O. Box 451 Princeton, N. J. 08543 mduco@pppl.gov (609)243-3787 (609)243-3373 -----Original Message----- From: Arthur W. Brooks Sent: Monday, March 26, 2007 8:27 AM To: Michael J. Duco Subject: A1 and A2 Fiducial Nominals Hi Mike, Can you forward me a copy of what you are now calling the nominals for all the fiducials for A1 and A2 (initial flange tooling balls plus added tooling balls)? I will apply the transform to them that I obtained from our Coil Realignment Process (ie the realignment to compensate for winding deviations) and return you new values for the nominals. I know the data is buried in the iges files you sent earlier, but we have multiple measurements of each point. I believe you selected one of the measurements to use as nominals (though they were all fairly close) Thanks, Art