From: Michael R. Kalish
Sent: Friday, March 02, 2007 8:09 AM
To: James H. Chrzanowski
Subject: FW: Coil Testing

Attachments: Electrical Test Turn to Turn Coil #1 before Ground Wrap.xls

From: Michael R. Kalish
Sent: Thursday, March 01, 2007 5:38 PM
To: 'J. Stafiniak'
Cc: Glenn Reinsmith; Irving J. Zatz; Robert J. Marsala; John Lawson; Thomas G. Meighan
Subject: RE: Coil Testing

 

John,

 

This actually looks like it makes sense.  I plotted your results (see attached). Can you document this in greater detail including the test setup etc. and include it in your MPO.  Are you ready to do the ring testing and impulse testing?  I would like for you to move ahead with the ground wrapping asap.

 

Thanks,

Mike

 

Michael Kalish
Princeton Plasma Physics Laboratory
PO Box 451    Princeton, NJ    08543
Phone: (609) 243-2277
Fax:   (609) 243-3248

You can visit the home page of the
Princeton Plasma Physics Laboratory at
http://www.pppl.gov


From: J. Stafiniak [mailto:jstafiniak@eversontesla.com]
Sent: Thursday, March 01, 2007 1:47 PM
To: Michael R. Kalish
Cc: Glenn Reinsmith
Subject: Coil Testing

 

Mike.

 

Here are the testing results on the actual coil ;

 

 

 

Voltage Across Coil Leads           Voltage on One Turn              Coil Current                      Turn To Turn Short

 with 750ohm betwn leads            of Growler Primary        (amprobe around 12 turns)          Resistance

 

 

750V                                           67.4                                     1.158                                open(no short)

 

749V                                           67.4                                     1.753                                10 ohms

 

752V                                           67.4                                     1.285                                50 ohms

 

751V                                           67.4                                     1.213                               100 ohms

 

751V                                           67.4                                     1.186                               200 ohms

 

750V                                           67.4                                     1.179                               250 ohms

 

749V                                           67.4                                     1.176                               300 ohms

 

750V                                           67.4                                     1.171                               350 ohms

 

750V                                           67.4                                     1.167                               400 ohms

 

750V                                           67.4                                     1.163                               500 ohms

 

 

 

The test results were not very sensitive to the location of the coil in the Growler but we fixtured it in place anyway. The same is true of the location of the amprobe around the coil.

 

 

 

Here are the test results of the 12 turns of lead wire wrapped around the Growler that we gave you over the phone a few days ago;

 

 

Voltage Across  Leads              Voltage on One Turn              Coil Current                      Turn To Turn Short

 with 750ohm betwn leads            of Growler Primary        (amprobe around 12 turns)          Resistance

 

 

750V                                           68.9                                     1.062                              open(no short)

 

752V                                           68.9                                     1.654                                10 ohms

 

752V                                           68.9                                     1.189                                50 ohms

 

752V                                           68.9                                     1.122                               100 ohms

 

751V                                           68.9                                     1.081                               200 ohms

 

751V                                           68.9                                     1.072                               250 ohms

 

751V                                           68.9                                     1.068                               300 ohms

 

752V                                           68.9                                     1.066                               350 ohms

 

751V                                           68.9                                     1.058                               400 ohms

 

751V                                           68.9                                     1.057                               500 ohms

 

 