From: Freudenberg, Kevin D. [freudenbergk@ornl.gov]
Sent: Thursday, June 22, 2006 2:28 PM
To: Wayne T. Reiersen; Bradley E. Nelson; Geoffrey J. Gettelfinger; David E. Williamson
Subject: Deflect-o-meter results

Attachments: C1 Analysis_6_22_06.ppt

All,

 

I looked over the video file for the deflection measurement system, very well done video by the way although the orientation was interesting to look at and interpret.  I have looked only at the full current shots thus far but it looks like we are in the ball park (not off by orders of magnitude) as for as the analysis prediction goes.  The deflection from the full current shots was  around .23 mm and ansys predicts somewhere between .3 - .55 mm.

 

 

All the best

 

Kevin