From: Nelson, 
Brad E. 
Sent: Monday, July 10, 
2006 6:50 PM
To: Freudenberg, 
Kevin D.
Subject: RE: files for 
strain gauges
Kevin
 
Here is a plot of SG15 
with the two room temp shots and an offset ANSYS plot, assuming 130 microstrain 
prediction at 36.5 kA.  There is still a linear piece of pie in the data, 
but it is pretty noisy.
 
Brad
 
 

Brad 
Nelson
nelsonbe@ornl.gov
voice:  
865-574-1507
fax: 865-576-7926
From: 
Freudenberg, Kevin D. 
Sent: 
Monday, July 10, 2006 4:25 PM
To: Nelson, Brad E.
Subject: files for strain 
gauges
 
Brad,
 
I have searched all the files and 
cannot find the current waveform.  maybe I missed it.  here are two 
files which may be of interest.
 
Look at the cool down profile of the 
gauges (2nd file) , looks weird to me, seems like temperature has a different 
effect on each gauge, 
 
Kevin