From: Fred Dahlgren Sent: Friday, May 16, 2008 12:30 PM To: Paul Goranson Cc: Mike Cole; Bob Simmons Subject: comments on ncsx-bspec-161-dA Paul, Just a few comments on the LN2 distribution SRD. Para.3.1 Typo. MCSX s/b NCSX Para.3.1.2.5 We need to know the mounting locations and total weight of the headers & flex lines - probably not required for the SRD though. Para.3.2.2.1-3.2.2.2 The mounting hardware & brackets also need to be designed to withstand the deflection of the the coil support structural components they are attached to during EM pulses & faults. (~ Dz & Dr ±0.02"). General: Some place in sections 3 & 4 there should be a stated requirement for leak tightness of all welded joints, couplings, & fittings. Should the non-flexible manifold material requirement be specified as 316L ss ? -Fred