| Review
Title |
Twisted
Racetrack Windings and Asm FDR |
| Date |
16 April 2004 |
| Cognizant
Engineer |
Dave Williamson |
|
Responsible Line Manager |
Brad Nelson |
|
Review Board Chairperson |
Larry Dudek |
|
Review Board Members |
P. Miller (ORNL), K.
Freudenberg (ORNL), P. Goranson (ORNL) |
|
Invited Attendees |
Judy Malsbury, Mike Cole
(ORNL), Jim Chrzanowski, Tom Brown, |
|
Other Attendees |
Steve Raftopoulos, Hutch,
Neilson, Geoff Gettelfinger, Phil Heitzenroeder |
|
Charge |
1) Does the design of the
twisted racetrack coil represent the desired features of the prototype
and production modular coil?
2) Does the design meet
requirements of a pre-prototype article for inspection, measurement,
diagnostics, and testing?
3) Are the models/drawings
of the chill pates and clamps ready for fabrication?
4) Is the design
consistent with plans for coil winding and VPI? |
|
Design Review Material |
Announcement
Presentation
Chits and Disposition |
|
Review Board Report |
|
|
Items Reviewed |
|
Sat |
Unsat |
Comments |
|
Appropriate requirements identified
|
 |
|
|
|
Development plans and schedules |
 |
|
|
|
Regulatory compliance including USQD and NEPA |
|
|
Not presented |
|
Disposition of CHITS from previous reviews |
|
|
N/A |
|
Cost
objectives |
|
|
Not presented |
|
Other
review objectives addressed
(Attachment 4 of ENG-033) |
|
|
|
|
Summary of Results
|
Review successful with resolution of CHITS
|
|
Disposition
(check
one) |
Acceptable |
Acceptable pending resolution of concerns -
CHITS identified above must be resolved prior to installation. |
|
Incomplete -
Additional design
work is required prior to another design review.
|
|
Cog Engineer Close-out
(check
when done) |
|
|
Action required by Disposition is complete |