        | Review
          Title | Modular Coil Winding 
		Dimensional Control Plan Peer Review |  
        | Date | 13 May  2005 |  
        | Cognizant
          Engineer | Brent Stratton |  
        | Responsible Line Manager | Brad Nelson |  
        | Review Board Chairperson | Michael Zarnstorff |  
        | Review Board Members | Mike Zarnstorff, Art Brooks, 
		Jim Chrzanowski, Mike Cole, Paul Fogarty, Phil Heitzenroeder, Brad 
		Nelson, Steve Raftopoulos, Wayne Reiersen, Dave Williamson, Simon 
		Anderson |  
        | Invitees | Mike Zarnstorff, Paul Fogarty, 
	Mike, Cole, Wayne Reiersen, Brad Nelson, Steve Raftopoulos, Art Brooks, Jim 
	Chrzanowski, Dave Williamson, Simon Anderson, Phil Heitzenroeder, Hutch Neilson, 
	Ron Strykowsky, Bob Simmons, Greg Pitonak, Jeff Makiel, Simon Anderson |  
        | Attendees | Art Brooks, Steve 
		Raftopoulos, Brent Stratton, Wayne Reiersen, Dave Williamson, Mike  
		Zarnstorff, Greg Pitonak, Paul Heitzenroeder |  
        | Charge | 1. Is the overall 
			structure of the plan adequate to ensure good dimensional control of 
			the coil windings? 
 2. Is a trial winding needed in order to achieve good dimensional 
			control? If so, is a trail winding needed on the first production 
			winding form, or on the first winding form of each type? Why?
 |  
        | Design Review Material | 
        
        Announcement 
        
		Presentation 
        
		Chits and Disposition Plan |  
        | Review Board Report |  |  
        | Items Reviewed | 
    
     | Sat | Unsat | Comments |  
        | Appropriate requirements identified |  |   |  |  
        | Development plans and schedules |  |   |  |  
        | Regulatory compliance including USQD and NEPA |  |   |  |  
        | Disposition of CHITS from previous reviews |  |   |  |  
        | Cost 
          objectives |  |   |  |  
        | 
          Other 
          review objectives addressed 
          
          (Attachment 4 of ENG-033) |  |   |  |  
        | 
          Summary of Results |  |  
        | 
          Disposition 
          (check 
     one) | 1  Acceptable |  
        | 1  Acceptable pending resolution of concerns - 
    CHITS identified above must be resolved prior to installation. |  
        | 1Incomplete -
    Additional design 
    work is required prior to another design review. |  
        | 
          Cog Engineer Close-out 
          (check 
     when done) |  |  
        | 1  
    Action required by Disposition is complete |  |